Air conditioning installation in Brisbane and suburbs
Jaric Air Conditioning specialises in the installation of both ducted and split systems for domestic and commercial use in all Brisbane suburbs. Our skilled, experienced and qualified installers will take care of everything for you, including the installation and electrical work required to get your system up and running.
How the Jaric team install the right air conditioner for your needs
Choosing the wrong air conditioning system can cost your home or business dearly over the long term. You’ll end up paying both for unnecessary running costs, and for the frustration of having an air con that’s simply not up to the job.
So when Jaric recommend the right air conditioner brand for your needs, we don’t just consider the size of the space to be cooled or heated. Instead, our expert air-conditioning team will take every aspect of your situation into account.
Jaric Electrical’s sales team and installers will work with your unique situation and find the best solution for your air con installation – every time.
Contact the Jaric team today
Standard back-to-back split system installation explained
- Installation of a high wall split system with the indoor head unit to be mounted on the inside of the external wall in a single storey property constructed with brick veneer or timber framed external walls.
- Indoor head unit installation to be positioned on plain internal wall. Head unit above windows, side exit or up and over, incur extra charge.
- Up to 2m vertical duct cover outside and 3m connection pipes and cables with standard pricing
- Condensate drain will be run 2m down and up to 2m across to a downpipe. Drain will be fitted with a 20mm relief for downpipe blockages.
- Outdoor condenser unit to be mounted to 900mm x 450mm poly slab
- All systems to have weatherproof isolator at outdoor position. Within 15m of connection source. Up to 5kw connected to general electrical circuit and 5kw – 9.5kw systems to have circuit run to switchboard with independent combo rcbo/circuit breaker.
- 5 years full Manufacturer’s Warranty Parts and Labour.
Split system installation extras
- Two storey back-to-back installation – $150
- Lifter for two storey on brackets or split level roof – $150
- Up and over 8m (6m over and 2m down do outdoor unit – $ 250
- Side entry installation – $50
- Extra distance between indoor and outdoor unit uncovered. – $ 45 per m
- Extra distance between indoor and outdoor unit covered. – $ 55 per m
- Electrical circuit over 15m – $ 5 per m
- Condensate drain over 4m – $4 per m
- De commission, removal and disposal of old split system – $100 inc gst
- Galvanised/powder coated wall bracket inc install (1.7kw – 4.5kw) – $ 100 inc gst
- Galvanised/powder coated wall bracket inc install (5.0kw – 9.5kw) – $ 150 inc gst
- Galvanised/powder coated roof bracket inc install (all sizes) – $ 165 inc gst
- Elevated feet and winter drain connection – $50 inc gst
- Double brick or extra penetration – $60 inc gst
- Core drilling may be applicable for concrete or tilt slab walls $220 inc
- Condensate pump (three options) to be quoted separately
- WiFi module if applicable – $195 inc gst
Standard ducted system installations explained
- Based on a single storey home.
- Installation of a split ducted system with the indoor head unit to be mounted into the ceiling space within the truss spacings of a single storey property with brick veneer or timber framed construction with tile or tin roof.
- Round insulated ceiling registers to be used in sizes of 200mm, 250mm or 300mm.
- Rectangle white plastic return air grill and filter with removable and washable centre and filter.
- Wall controller to be mounted to central position of house.
- Condensate drain to be run to gutter.
- Outdoor condenser unit to be positioned at customers choice within 15m of outdoor unit.
- Outdoor condenser unit to be mounted onto a poly slab if bare ground.
- If the piping has to be reused as its run internally run and not accessible, we do not warrant the existing piping or drainage in any way.
- Standard Manufacture unit controller, coupled with zone controller if applicable.
- Weatherproof isolator with independent electrical circuit run from system to switchboard, with correctly sized safety circuit breaker.
- 5 years full Manufacturer’s Warranty Parts and Labour.
- Terms of Trade applicable.
Ducted system installation extras – prices on request
- Zone controller standard on/off up to 6 zones
- Additional ceiling outlets
- Upgrade to My Air with individual air flow control for each zone 6 zones
- Additional zones up to 10
- Sensors to allow zones to be temperature controlled